MDR-60W is designed with plastic housing, can effectively prevent the user’s electrical hazards, working efficiency of up to 87%, under the condition of air circulation, the whole series can work in the ambient temperature of -20°C to 70°C, it has a complete protection function and conforms to the home automation, industrial control equipment IEC/EN62368-1, Standards such as IEC/EN55032 (CISPR32), IEC/EN61000-3-2) make the MDR-60W a highly competitive power solution for home and industrial applications.
Application:
Home control system
Building Automation
Industrial control systems
Factory Automation
Mechanical and electrical equipment
Product Specifications
Model
MDR-60-5
MDR-60-12
MDR-60-24
MDR-60-48
Output
DC output voltage
5V
12V
24V
48V
Rated output current
10A
5A
2.5A
1.25A
Output current range
0~10A
0~5A
0~2.5A
0~1.25A
Rated power
50W
60W
60W
60W
Ripple noise
80mvp-p
120mvp-p
150mvp-p
200mvp-p
Voltage adjustment range
5~6V
12~15V
24~30V
48~56V
Voltage accuracy
±2.0%
±1.0%
±1.0%
±1.0%
Linear adjustment rate
±1.0%
±1.0%
±1.0%
±1.0%
Load adjustment rate
±1.5%
±1.0%
±1.0%
±1.0%
Start, rise, hold time
500ms,30ms,50ms/230VAC 500ms,30ms,20ms/115VAC(At full load)
Input
Input voltage range
100~240VAC,47~63Hz,141~339VDC
Efficiency
0.78
0.85
0.87
0.87
Alternating current
1.8A/115VAC,1A/230VAC
Inrush current
Cold start current 30A/115VAC,60A/230VAC
Leakage current
<1mA/240VAC
Protection
Over load
105%~150% of rated output power
Protection mode: constant current limit, automatic recovery after load abnormal conditions are removed
Over voltage
6.25~7.25V
15.6~18V
31.2~36V
57.6~64.8V
Protected mode: The output voltage is turned off and recovered after restart
Feature
DC OK signal
Relay contacts (Max.) : 30V/1A resistive load
Environment
Working temp,humidity
-20℃~+70℃,20%~90%RH
Storagetemp,humidity
-40℃~+85℃,10%~95%RH non-condensing
Temperature coefficient
±0.03%/°C(0-50°C)
Withstand vibration
10~500Hz,2G 10min./1 cycle, X, Y, Z 60 minutes each; Installation: According to IEC60068-2-6
Safety
Withstand voltage
I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
Isolated resistance
I/P-O/P,I/P-FG,O/P-FG:>100M Ohms/500VDC/25℃/70%RH
Fit standard
Safety standards
IEC/EN62368-1, EN61558-1
EMC emission
Complies with IEC/EN55032 (CISPR32) class A, IEC/EN61000-3-2, class A
EMC immunity
Comply with IEC/EN55035, IEC/EN61000-6-2, IEC/EN61000-4-2, 3, 4, 5, 6, 8
Others
Dimension
40* 90 * 100 mm ( W* H* D)
Weight/packing
0.33kg / 42PCS /14.8 kg / 0.82 CUFT
Note
1.Unless otherwise specified, all parameters are measured under 230VAC voltage input, rated load, and 25 ° C conditions.
2. Ripple and noise voltage were measured on a 20MHz bandwidth oscilloscope with 0.1 μ and 47 μ capacitors added to the end of a 12 inch twisted pair cable.
3. Accuracy: including setting error, linear adjustment rate, and load adjustment rate.
4. The power supply is considered as an independent component, but the final power supply still needs to be confirmed for electromagnetic compatibility with the terminal device.
5. The start-up time is measured during cold start, and frequent power on and off may result in longer start-up time.
Dimensional Drawing
Block Diagram
DC OK Relay Triggered
Contact closure
The power supply /DC is normal
Contact open
The power supply is off or the DC is faulty
Contact (Max.)
30V/1A resistive load
Get A Quote