Our website uses cookies to improve your experience and record usage statistics. By using our site you consent to cookies as described in our Privacy Policy. We take your privacy and data security very seriously and all information collected will be kept strictly confidential.
The SC-120W series is a 120W single output with Battery Charging function (UPS) power supply with 100 to 240VAC full range AC input and 12V,24V output throughout the series. In addition to the 86% efficiency, the metal mesh housing design enhances the heat dissipation capability, enabling the SC-120W to operate without a fan in the temperature range of -10°C to +50°C, making it easy for the end system to meet international energy requirements.
Features :
International universal full range AC input
Small size, light weight, high efficiency
Protection feature: short circuit/over load
With power on/charge/mains display (LED)
100% full load burn test
Battery low voltage protection
2 years quality guarantee
Application:
Industrial automation machinery
Industrial control systems
Mechanical and electrical equipment
Electronic instruments, equipment and devices
Product Specifications
Specifications
Model
SC-120-12
SC-120-24
Output
DC output voltage
CH1:13.8V
CH2:13.4V
CH1:27.6V
CH2:26.5V
Output voltage tolerance
±1%
——
±1%
——
Rated output current
8.A
0.5A
4.0A
0.25A
Output current range
0~8A
——
0~4A
——
Output power
117.1W
118.4W
Ripple noise
120mVp-p
——
120mVp-p
——
DC voltage adjustable range
CH1:11.3~14.9V
CH2:21.3~29.8V
Start, rise, hold time
600ms,50ms,80ms/230VAC 1200ms,50ms,16ms/115VAC(At full load)
Input
Input voltage range
100~240VAC,141~339VDC
AC input voltage
2.8A/115VAC 1.4A/230VAC
Efficiency
0.84
0.86
Impulse current
Cold start current 30A/115VAC 50A/230VAC
Leakage current
<1mA/240VAC
Protection
Over load
Start overload protection for 110% to 150% of rated output power
Protection mode: AC charging mode: In isolation mode, the load can be automatically restored after abnormal conditions are removed
Environment
Low-voltage
battery protection
9.5~11V
20~22V
Protected mode: Output is cut off
UPS Function Description
The long-term online floating charge of the battery, high charging efficiency, and the battery fullness can be ashigh as 90%
Full automatic stop, prevent the battery overcharge, effectively extend the battery life
Automatic mains/battery switching, no switching time, no need to watch
With the cold start function, the UPS can be started directly with the battery to meet the emergency requirements of users when there is no mains supply
Working temp,humidity
-10°C~+60°C; 20%~90%RH, no condensation (please refer to the load derating curve)
Storage temp& humidity
-20°C~+85°C; 10%-95% RH Non-condensing
Seismic resistance
10~500Hz, 2G 10min./1 cycle, duration 60 minutes, each axis
Safety
Voltage resistance
I/P-O/P:1.5KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
Insulation resistance
I/P-O/P,I/P-FG,O/P-FG:100M ohms/500VDC
Fit standard
Safety standards
Conforms to UL60950-1
EMC standard
Complies with EN55032 Class B
Others
Dimension
159*97*38mm (L*W*H)
Weight/packing
0.56kg/45pcs/26kg/0.041m³/1.45CUFT
Note
1. All parameters, unless otherwise specified, are measured at 230VAC input voltage, rated load and 25°C.
2. Ripple and noise voltages are measured on a 20MHz bandwidth oscilloscope with a 12-inch twisted pair end and a capacitor of 0.1 μand 47 μ.
3. Tolerance is the sum of voltage setting error, voltage adjustment rate and current adjustment.
Dimensional Drawing
Dimensional drawing
Block diagram
Get A Quote
Further information or a personal consultation? Our products and know-how
are there to provide solutions.