250W Ultra-thin Performance AC/DC Enclosed SMPS Power Supply

  • AC voltage input range is switched by switching
  • Can withstand 300vac surge input for 5 seconds
  • Small size (1U low shell), light weight
  • Protection characteristics: short circuit/over load/over voltage/over temperature
  • Air cooling
  • Low no-load power (<1W)
  • With power-on display (LED)
  • 100% full load burn test
  • High efficiency, long life and high reliability
  • LED power indicator
  • 2-year quality guarantee
Get A Quote
Product Description

The LRS-250E series is a 250W single-output enclosed power supply with a 30mm low profile design with 115VAC or 230VAC segmented input (via switch selection) and 12V,15V,24V,36V and 48V outputs throughout the series.

 

Features :

  • AC voltage input range is switched by switching
  • Can withstand 300vac surge input for 5 seconds
  • Small size (1U low shell), light weight
  • Protection characteristics: short circuit/over load/over voltage/over temperature
  • Air cooling
  • Low no-load power (<1W)
  • With power-on display (LED)
  • 100% full load burn test
  • High efficiency, long life and high reliability
  • LED power indicator
  • 2-year quality guarantee

 

Application:

  •  Industrial automation machinery
  • Industrial control systems
  • Mechanical and electrical equipment
  • Electronic instruments, equipment and devicesces

 

Product Specifications

Specifications

Model LRS-250E-12 LRS-250E-15 LRS-250E-24 LRS-250E-36 LRS-250E-48
DC voltage 12V 15V 24V 36V 48V
Rated current 20A 16A 10A 6.67A 5A
Current range 0~20A 0~16A 0~10A 0~6.67A 0~5A
Rated power 240W 240W 240W 240.1W 240W
Ripple&noise 150mVp-p 200mVp-p 300mVp-p 400mVp-p 500mVp-p
Adjustable range of DC voltage ±10% ±10% ±10% ±10% ±10%
Output Excellent voltage ±2% ±1% ±1% ±1% ±1%
Linear adjustment rate ±0.5% ±0.5% ±0.5% ±0.5% ±0.5%
Load adjustment rate ±1% ±0.5% ±0.5% ±0.5% ±0.5%
Start, rise, hold time 800ms,50ms,16ms/230VAC(At full load)
Input Input voltage range 100~120VAC/200~240VAC,47~63Hz,282~339VDC
AC input voltage 5.0A/115VAC  2.5A/230VAC
Efficiency 0.87 0.88 0.89 0.89 0.9
Surge current Cold start current 55A/230VAC
Leakage current <2mA/240VAC
Protection Over load Start overload protection for 110% to 140% of rated output power
Protection mode: In isolation mode, normal output can be automatically restored after abnormal conditions are removed
Overvoltage protection Start overvoltage protection for 115%~135% of the rated output voltage
Protection mode: In isolation mode, normal output can be automatically restored after abnormal conditions are removed
Overtemperature protection 110°C±10°C(RTH3 is detected next to the magnetic ring)
Protection mode: In isolation mode, the temperature can be automatically restored after returning to normal
Environment Working temp,humidity -20℃~+60℃,20%~90%RH
Storage temp& humidity -40℃~+85℃,10%~95%RH non-condensing
Withstand vibration 10~500Hz, 3G 10min./1 cycle, duration 60 minutes, each axis
Safety Withstand voltage I/P-O/P:1.5KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
Isolated resistance I/P-O/P,I/P-FG,O/P-FG:100M ohms/500VDC/25°C/70%RH
Fit standard Safety standards Conforms to UL60950-1, IEC/EN62368
EMC emission Conforms to EN55032(CISPR22)Class A,IEC/EN61000-3-2, Class A
EMC immunity Comply with IEC/EN55035, IEC/EN61000-6-2, IEC/EN61000-4-2, 3,4, 5,6, 8
Others Dimension 215*115*30mm (L*W*H)
Weight/packing 0.66kg/24pcs/16.8kg/0.027m³/0.96CUFT
Note 1. All parameters, unless otherwise specified, are measured at 230VAC input voltage, rated load and 25°C.
2. Ripple and noise voltages are measured on a 20MHz bandwidth oscilloscope with a 12-inch twisted pair end and a capacitor of 0.1 μand 47 μ.
3. Accuracy: voltage setting error, linear adjustment rate and load adjustment rate.
4. Linear adjustment rate measurement method: under rated load, from low voltage to high voltage test.
5. Load adjustment rate measurement method: from 0% to 100% rated load.
6. The power supply should be considered as part of the components in the system, and the electromagnetic compatibility should be confirmed in conjunction with the terminal equipment.

Dimensional Drawing

Dimensional drawing

Block diagram

 

Get A Quote

Further information or a personal consultation? Our products and know-how are there to provide solutions.

RELATED PRODUCTS
RELATED NEWS
YOU MAY ALSO WANT TO SEE
GET A QUOTE TODAY!
icon
icon
Seraphinite AcceleratorOptimized by Seraphinite Accelerator
Turns on site high speed to be attractive for people and search engines.