| Model | LRS-250E-12 | LRS-250E-15 | LRS-250E-24 | LRS-250E-36 | LRS-250E-48 |
| DC voltage | 12V | 15V | 24V | 36V | 48V |
| Rated current | 20A | 16A | 10A | 6.67A | 5A |
| Current range | 0~20A | 0~16A | 0~10A | 0~6.67A | 0~5A |
| Rated power | 240W | 240W | 240W | 240.1W | 240W |
| Ripple&noise | 150mVp-p | 200mVp-p | 300mVp-p | 400mVp-p | 500mVp-p |
| Adjustable range of DC voltage | ±10% | ±10% | ±10% | ±10% | ±10% |
| Output | Excellent voltage | ±2% | ±1% | ±1% | ±1% | ±1% |
| Linear adjustment rate | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% |
| Load adjustment rate | ±1% | ±0.5% | ±0.5% | ±0.5% | ±0.5% |
| Start, rise, hold time | 800ms,50ms,16ms/230VAC(At full load) |
| Input | Input voltage range | 100~120VAC/200~240VAC,47~63Hz,282~339VDC |
| AC input voltage | 5.0A/115VAC 2.5A/230VAC |
| Efficiency | 0.87 | 0.88 | 0.89 | 0.89 | 0.9 |
| Surge current | Cold start current 55A/230VAC |
| Leakage current | <2mA/240VAC |
| Protection | Over load | Start overload protection for 110% to 140% of rated output power |
| Protection mode: In isolation mode, normal output can be automatically restored after abnormal conditions are removed |
| Overvoltage protection | Start overvoltage protection for 115%~135% of the rated output voltage |
| Protection mode: In isolation mode, normal output can be automatically restored after abnormal conditions are removed |
| Overtemperature protection | 110°C±10°C(RTH3 is detected next to the magnetic ring) |
| Protection mode: In isolation mode, the temperature can be automatically restored after returning to normal |
| Environment | Working temp,humidity | -20℃~+60℃,20%~90%RH |
| Storage temp& humidity | -40℃~+85℃,10%~95%RH non-condensing |
| Withstand vibration | 10~500Hz, 3G 10min./1 cycle, duration 60 minutes, each axis |
| Safety | Withstand voltage | I/P-O/P:1.5KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC |
| Isolated resistance | I/P-O/P,I/P-FG,O/P-FG:100M ohms/500VDC/25°C/70%RH |
| Fit standard | Safety standards | Conforms to UL60950-1, IEC/EN62368 |
| EMC emission | Conforms to EN55032(CISPR22)Class A,IEC/EN61000-3-2, Class A |
| EMC immunity | Comply with IEC/EN55035, IEC/EN61000-6-2, IEC/EN61000-4-2, 3,4, 5,6, 8 |
| Others | Dimension | 215*115*30mm (L*W*H) |
| Weight/packing | 0.66kg/24pcs/16.8kg/0.027m³/0.96CUFT |
| Note | 1. All parameters, unless otherwise specified, are measured at 230VAC input voltage, rated load and 25°C.
2. Ripple and noise voltages are measured on a 20MHz bandwidth oscilloscope with a 12-inch twisted pair end and a capacitor of 0.1 μand 47 μ.
3. Accuracy: voltage setting error, linear adjustment rate and load adjustment rate.
4. Linear adjustment rate measurement method: under rated load, from low voltage to high voltage test.
5. Load adjustment rate measurement method: from 0% to 100% rated load.
6. The power supply should be considered as part of the components in the system, and the electromagnetic compatibility should be confirmed in conjunction with the terminal equipment. |