Our website uses cookies to improve your experience and record usage statistics. By using our site you consent to cookies as described in our Privacy Policy. We take your privacy and data security very seriously and all information collected will be kept strictly confidential.
The MS-120W series is a 120W single-output closed power supply with a 38mm low profile design and a global voltage input, providing 12V, 15V, 24V, 27V output throughout the series. The design of the metal mesh housing gives it excellent low electromagnetic emission interference, and enhances the heat dissipation capacity, so that the MS-120W can operate in the temperature range of -20 ° C to +60 ° C without a fan.
Features :
International input voltage range
Small size, light weight and high efficiency
Protection characteristics: short circuit/overload/overvoltage
Air cooling
With power-on display (LED)
Low no-load power consumption
100% full load burn test
2-year quality guarantee
Application:
Industrial automation machinery
Industrial control systems
Mechanical and electrical equipment
Electronic instruments, equipment and devices
Product Specifications
Specifications
Model
MS-120-12
MS-120-15
MS-120-24
MS-120-27
Output
DC output voltage
12V
15V
24V
27V
Output voltage tolerance
±2%
±1.5%
±1.5%
±1.5%
Rated output current
10A
8A
5A
4.5A
Output current range
0~10A
0~8A
0~5A
0~4.5A
Output power
120W
120W
120W
121.5W
Ripple noise
120mVp-p
150mVp-p
240mVp-p
300mVp-p
DC voltage adjustable range
-9%~+10%
-9%~+10%
-9%~+10%
-9%~+10%
Start, rise, hold time
800ms,50ms,24ms/230VAC 1200ms,30ms,20ms/115VAC
Input
Input voltage range
100~240VAC,47~63Hz,141~339VDC
AC input voltage
2.6A/115VAC 1.4A/230VAC
Efficiency
0.86
0.88
0.88
0.88
Surge current
Cold start current 65A/230VAC
Leakage current
<0.5mA/240VAC
Protection
Overload protection
Start overload protection for 110% to 150% of rated output power
Protection mode: In isolation mode, the load can be automatically restored after abnormal conditions are removed
Overvoltage protection
Start overvoltage protection for 120%~150% of rated output voltage
Protection mode: In isolation mode, abnormal conditions can be automatically restored after removal
Environment
Working temp,humidity
-20℃~+60℃,20%~90%RH
Storage temp& humidity
-40℃~+85℃,10%~95%RH non-condensing
Withstand vibration
10~500Hz, 2G 10min./1 cycle, duration 60 minutes, each axis
Safety
Withstand voltage
I/P-O/P:1.5KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
Isolated resistance
I/P-O/P,I/P-FG,O/P-FG:100M ohms/500VDC
Fit standard
Safety standard
Conforms to UL60950-1, CB(IEC60950-1),GB4943
EMC standard
Conforms to EN55022(CLSPR22)Class A, EN61000-3-2, EN55024,EN61000-6-1
Others
Dimension
129*98*38mm (L*W*H)
Weight/packing
0.45kg/45pcs/21kg/0.035m³/1.24CUFT
Note
1. All parameters are measured at 230VAC voltage input, rated load and 25℃ when not specified.
2. Ripple and noise voltages are measured on a 20MHz bandwidth oscilloscope with a 12-inch twisted pair end and a capacitor of 0.1 μand 47 μ.
3. Tolerance is the sum of voltage setting error, voltage adjustment rate and current adjustment rate.
Dimensional Drawing
Dimensional drawing
Block diagram