NES-600W series is a 600W single output closed power supply, with 65mm low profile design, global voltage input, the whole series provides 12V,15V,24V,36V,48V output, efficiency of up to 90%, metal shell design makes it has excellent low electromagnetic emission interference, built-in long-life DC fan, The NES-600W can work with full load in the temperature range of -20℃ to +60℃.
Features :
The international common AC input voltage range is switched by the switch
Small size, light weight and high efficiency
Protection characteristics: short circuit/overload/overvoltage/overtemperature
Built-in cooling DC fan
Built-in wind speed control circuit
With power-on display (LED)
100% full load burn test
LED power indicator
2-year quality guarantee
Application:
Industrial automation machinery
Industrial control systems
Mechanical and electrical equipment
Electronic instruments, equipment and devices
Product Specifications
Specifications
Model
NES-600-12
NES-600-15
NES-600-24
NES-600-36
NES-600-48
Output
DC output voltage
12V
15V
24V
36V
48V
Output voltage tolerance
±2%
±2%
±2%
±2%
±2%
Rated output current
50A
40A
25A
16.7A
12.5A
Output current range
0~50A
0~40A
0~25A
0~16.7A
0~12.5A
Output power
600W
600W
600W
601.2W
600W
Ripple noise
150mVp-p
180mVp-p
300mVp-p
400mVp-p
500mVp-p
DC voltage adjustable range
-9%~+10%
±10%
±10%
±10%
±10%
Start, rise, hold time
500ms,50ms,16ms/230VAC(At full load)
Input voltage range
100~120VAC/200~240VAC(selected by switch),47~63Hz,282~339VDC
AC input voltage
12A/115VAC 6A/230VAC
Efficiency
0.86
0.86
0.88
0.89
0.9
Impulse current
Cold start current 45A/115VAC 60A/230VAC
Input
Leakage current
<3.5mA/240VAC
Protection
Overload protection
Start overload protection for 110% to 135% of rated output power
Protection mode: In isolation mode, normal output can be automatically restored after abnormal conditions are
removed
Overvoltage protection
Start overvoltage protection for 115%~135% of the rated output voltage
Protection mode: In isolation mode, normal output can be automatically restored after abnormal conditions ar
removed
Overtemperature protection
Power tube temperature ≥95°C±5% start overtemperature protection
Protection mode: Cut off the output, and automatically restore when the temperature returns to normal
Environment
Working temp,humidity
-20°C~+60°C; 20%~90%RH
Storage temp& humidity
-40℃~+85℃,10%~95%RH non-condensing
Withstand vibration
10~500Hz, 3G 10min./1 cycle, duration 60 minutes, each axis
Safety
Withstand voltage
I/P-O/P:1.5KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
Isolated resistance
I/P-O/P,I/P-FG,O/P-FG:100M ohms/500VDC/25°C/70%RH
Fit standard
Safety standards
Conforms to UL60950-1, IEC/EN62368
EMC emission
Conforms to EN55032(CISPR22)Class A,IEC/EN61000-3-2, Class A
EMC immunity
Comply with IEC/EN55035, IEC/EN61000-6-2, IEC/EN61000-4-2, 3,4, 5,6, 8
Others
Dimension
238*124*65mm (L*W*H)
Weight/packing
1.5kg/12pcs/19kg/0.033m³/1.18CUFT
Note
1. All parameters, unless otherwise specified, are measured at 230VAC input voltage, rated load and 25°C.
2. Ripple and noise voltages are measured on a 20MHz bandwidth oscilloscope with a 12-inch twisted pair end and a capacitor of 0.1 μand 47 μ.
3. Tolerance is the sum of voltage setting error, voltage adjustment rate and current adjustment rate.
4. The power supply should be considered as part of the components in the system, and the electromagnetic compatibility should be confirmed in conjunction with the terminal equipment.
Dimensional Drawing
Dimensional drawing
Block diagram