The LRS-50E series is a 50W single-output enclosed power supply with a 30mm low profile design and a full range of AC inputs from 100 to 240VAC, with 5V,12V,15V,24V,36V and 48V outputs available throughout the series.
Features :
International general AC voltage input
Can withstand 300vac surge input for 5 seconds
Small size (1U low shell), light weight
Protection characteristics: short circuit/over load/over voltage
Air cooling
Low no-load power (<1W)
Can be operated at an altitude of 2000 m (Note 6)
With power-on display (LED)
100% full load burn test
High efficiency, long life and high reliability
LED power indicator
2-year quality guarantee
Application:
Industrial automation machinery
Industrial control systems
Mechanical and electrical equipment
Electronic instruments, equipment and devicesces
Product Specifications
Specifications
Model
LRS-50E-5
LRS-50E-12
LRS-50E-15
LRS-50E-24
LRS-50E-36
LRS-50E-48
Output
DC voltage
5V
12V
15V
24V
36V
48V
Rated current
10A
4.2A
3.4A
2.2A
1.45A
1.1A
Current range
0~10A
0~4.2A
0~3.4A
0~2.2A
0~1.45A
0~1.1A
Rated power
50W
50.4W
51W
52.8W
52.2W
52.8W
Ripple&noise
100mVp-p
120mVp-p
150mVp-p
240mVp-p
400mVp-p
500mVp-p
Adjustable range of DC voltage
±10%
±10%
±10%
±10%
±10%
±10%
Excellent voltage
±3%
±2%
±1%
±1%
±1%
±1%
Linear adjustment rate
±0.5%
±0.5%
±0.5%
±0.5%
±0.5%
±0.5%
Load adjustment rate
±2%
±1%
±0.5%
±0.5%
±0.5%
±0.5%
Start, rise, hold time
800ms,30ms,30ms/230VAC(At full load)
Input
Input voltage range
100~240VAC,47~63Hz,141~339VDC
AC input voltage
0.95A/115VAC 0.56A/230VAC
Efficiency
0.83
0.86
0.87
0.88
0.89
0.9
Surge current
Cold start current 45A/230VAC
Leakage current
<0.75mA/240VAC
Protection
Over load
Start overload protection for 110% to 150% of rated output power
Protection mode: In isolation mode, normal output can be automatically restored after abnormal conditions are removed
Overvoltage protection
Start overvoltage protection for 120%~150% of rated output voltage
Protection mode: In isolation mode, normal output can be automatically restored after abnormal conditions are removed
Environment
Working temp,humidity
-20℃~+60℃,20%~90%RH
Storage temp& humidity
-40℃~+85℃,10%~95%RH non-condensing
Withstand vibration
10~500Hz, 3G 10min./1 cycle, duration 60 minutes, each axis
Safety
Withstand voltage
I/P-O/P:1.5KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
Isolated resistance
I/P-O/P,I/P-FG,O/P-FG:100M ohms/500VDC/25°C/70%RH
Fit standard
Safety standards
Conforms to UL60950-1, IEC/EN62368
EMC emission
Conforms to EN55032(CISPR22)Class A,IEC/EN61000-3-2, Class A
EMC immunity
Comply with IEC/EN55035, IEC/EN61000-6-2, IEC/EN61000-4-2, 3,4, 5,6, 8
Others
Dimension
99*82*30mm (L*W*H)
Weight/packing
0.21kg/60pcs/13.7kg/0.029m³/1.04CUFT
Note
1. All parameters, unless otherwise specified, are measured at 230VAC input voltage, rated load and 25°C.
2. Ripple and noise voltages are measured on a 20MHz bandwidth oscilloscope with a 12-inch twisted pair end and a capacitor of 0.1 μand 47 μ.
3. Accuracy: voltage setting error, linear adjustment rate and load adjustment rate.
4. Linear adjustment rate measurement method: under rated load, from low voltage to high voltage test.
5. Load adjustment rate measurement method: from 0% to 100% rated load.
6. When the operating altitude is higher than 2000 m (6500ft), adjust the operating environment by 5°C/1000 m.
7. The power supply should be considered as part of the components in the system, and the electromagnetic compatibility should be confirmed in conjunction with the terminal equipment.