Aluminum Lightweight Industrial Waterproof LED Driver 240W

Wide voltage range input (100VAC~240VAC)
Excellent temperature adaptability (-30°C~+70°C)
Less than 0.8W no-load power consumption
No fan design, 240W natural air cooling
Advanced active PEC (PF>0.98)
Comprehensive protection function: short circuit/over load/over voltage/over temperature
Redundant EMC design for control systems and equipment sensitive to electromagnetic interference
Fully protected aluminum housing, fully irrigated, meets IP65/IP67 protection rating, can be installed indoors or outdoors
Suitable for dry, wet and rainy environment
Function Optional: 3-in-1 dimming (dim-to-off) (refer to dimming function introduction)
100% full load burn test
High efficiency, high power density, long life and high reliability
3-year quality guarantee

Get A Quote
Product Description

HPV-240 series is a 240W single output LED power supply, constant current and constant voltage as the main design features. Optional 3-in-1 dimming function, the use of global universal AC input voltage range, active PFC circuit and advanced power conversion system, in addition to peak efficiency of up to 92.5%, built-in 105°C long life well-known brand electrolytic capacitor, making the series of products in the natural air cooling of -30°C to +70°C for a long time reliable operation.

 

Features :

Wide voltage range input (100VAC~240VAC)
Excellent temperature adaptability (-30°C~+70°C)
Less than 0.8W no-load power consumption
No fan design, 240W natural air cooling
Advanced active PEC (PF>0.98)
Comprehensive protection function: short circuit/over load/over voltage/over temperature
Redundant EMC design for control systems and equipment sensitive to electromagnetic interference
Fully protected aluminum housing, fully irrigated, meets IP65/IP67 protection rating, can be installed indoors or outdoors
Suitable for dry, wet and rainy environment
Function Optional: 3-in-1 dimming (dim-to-off) (refer to dimming function introduction)
100% full load burn test
High efficiency, high power density, long life and high reliability
3-year quality guarantee

 

Application:

LED street lighting
LED wall wash light
LED patio lights
LED greenhouse lighting
LED floodlight
Electronic instruments, equipment and devices

Product Specifications

Specifications

Model HPV-240-12 HPV-240-24
Output Output DC current 12V 24V
Constant current range
(load CV mode)
No constant current function 16~24V
Constant current
(load CV mode)
No constant current function 11A±0.5A
Rated output current
(load CC mode)
16.5A 10A
Rated output power 240W 240W
Ripple noise (Max.) 200mVp-p 240mVp-p
Voltage accuracy ±2% ±2%
Linear adjustment rate ±0.5% ±0.5%
Load adjustment rate ±2% ±2%
Start, rise, hold time 25°C 500ms,100ms,10ms/230VAC   1000ms,100ms,10ms/115VAC(At full load)
Input Dynamic load characteristic Test condition: Load ≥20Hz dynamic jump. Jump range: load rated current 0.07%~100%
Ripple <1000mVP-P(dynamic load ripple is less than 5% of rated voltage, no obvious
audible noise, input power is stable and does not flicker)
Operating voltage range 100~240VAC,141~339VDC(refer to derating curve); (Can withstand 300VAC surge input
for 5 seconds without damage)
Rated voltage range 100VAC~240VA(refer to derating curve)
Frequency range 47Hz~63Hz
Input current <2A/115VAC;<1.0A/230VAC;<0.8A/270VAC
Power factor PF≥0.99/115VAC,PF≥0.98/230VAC(full load)
Efficiency 92.5% (full load, input 230VAC, no line loss)
Inrush current Cold start current 45A/230VAC
Leakage current <0.75mA/277VAC
Protection Overvoltage protection 95%~108% of the rated output current, start overcurrent protection
Constant current limit, the load can be automatically restored after abnormal conditions are
removed
Overcurrent protection Start overvoltage protection for 115%~120% of the rated output voltage
Turn off the output voltage and restart to restore
Overtemperature protection 95°C±10°C(thermostat close to PFCA radiator)
Turn off the output voltage and restart to restore
Short circuit protection When the load impedance is 0 due to an abnormal load, the system enters the short-circuit
protection mode and can short-circuit for a long time
Constant current limit, the load can be automatically restored after abnormal conditions are
removed
Environment Operating temperature
and humidity
-30°C~+70°C; 20%~90%RH, no condensation
(Warning: Please refer to the load derating curve for operating temperature)
Storage temperature and
humidity
-40°C~+85°C; 10%~95%, no condensation
Maximum enclosure
temperature
80°C(measured at ambient temperature of 25°C)
Shock resistance and
impact
10Hz~500Hz, acceleration 2G 10min./1 cycle, duration 60 minutes, X, Y, Z axis for 6
sweep cycles
Safety Insulation strength and
leakage current
I/P~O/P :3KVAC/10mA; I/P~FG :1.5KVAC/10mA; O/P~FG :0.5KVDC/10mA
Insulation impedance Input and output: 10MΩ; Input and housing: 10MΩ; Output and housing: 10MΩ
Ground resistance 32A/1 min (40A/2 min for UL certified models); Ground resistance <0.1ohms
Fit standard Safety standard Conforms to EN61347-1, GB19510
EMC emission Conforms to EN55015(CISPR22)Class B,GB/17743 Class B,GB17625.1,EN61000-3-2, -3
EMC immunity Conforms to EN61000-4-2, 3, 4, 5, 6, 8, 11
Others Dimension 245*72*38mm (L*W*H)
Package 1.3kg/15pcs/20.5kg/0.92CUFT/0.026m³
Design MTBF At 25°C, 100,000 Hrs, MIL-217 Method 2 Components Stress Method
Weight/packing >5 years (test conditions: ambient temperature 50°C, input 230VAC, refer to derating
curve for details)
Note 1. All parameters are measured at 230VAC voltage input, rated load and 25°C, unless otherwise specified.
2. Ripple and noise voltage is tested on a 20MHz bandwidth oscilloscope with a 12-inch twisted pair end and a capacitor of 0.1 μand 47 μ.
3. Voltage accuracy includes: voltage setting error, linear adjustment rate and load adjustment rate (voltage is the test value of the power port)
4. Linear adjustment rate measurement method: under rated load, from low voltage to high voltage test (voltage is the power port test value)
5. Load adjustment rate measurement method: from 0% to 100% rated load (voltage is the power port test value)
6. The power supply should be regarded as part of the components in the system, and the electromagnetic compatibility should be confirmed in combination with the terminal equipment; The specification relates to EMC standards that are only responsible for this product.
Dimensional Drawing

Dimensional Drawing

 

 

Block Diagram

 

 

Power Factor Characteristic Curve

Get A Quote

Further information or a personal consultation? Our products and know-how are there to provide solutions.

RELATED PRODUCTS
RELATED NEWS
YOU MAY ALSO WANT TO SEE
GET A QUOTE TODAY!
icon
icon
Seraphinite AcceleratorOptimized by Seraphinite Accelerator
Turns on site high speed to be attractive for people and search engines.