Our website uses cookies to improve your experience and record usage statistics. By using our site you consent to cookies as described in our Privacy Policy. We take your privacy and data security very seriously and all information collected will be kept strictly confidential.

Decline All Accept All

Ultra-thin PFC-Standard Enclosed Switching Power Supply 500W

  • International universal full range of AC input
  • Built-in active PFC function
  • Efficiency up to 90.5%
  • Built-in DC fan for forced cooling
  • Remote control switch/remote sensing function
  • Protection type: short circuit/over load/over voltage/over temperature
  • 3-year quality guarantee

 

Get A Quote
Product Description

The RSP-500W series is a 500W single-output housing type AC to DC power supply. The full range of input voltages ranges from 100 to 240VAC and provides DC outputs to meet most industrial needs. Each model can be air-cooled by an internal speed fan with an operating temperature of 70°C. In addition, the RSP-500W offers design flexibility with built-in features such as remote on/off control and remote sensing.

 

Features :

International universal full range of AC input
Built-in active PFC function
Efficiency up to 90.5%
Built-in DC fan for forced cooling
Remote control switch/remote sensing function
Protection type: short circuit/over load/over voltage/over temperature
3-year quality guarantee

 

Application:

Industrial control or automation devices
Test and measurement instruments
Laser related machines
Aging equipment

Specifications

Specifications

Model RSP-500-12 RSP-500-15 RSP-500-24 RSP-500-27 RSP-500-48
Output DC voltage 12V 15V 24V 27V 48V
Rated voltage 41.7A 33.4A 21A 18.6A 10.5A
Current range 0~41.7A 0~33.4A 0~21A 0~18.6A 0~10.5A
Rated power 500.4W 501W 504W 502.2W 504W
Ripple noise 150mVp-p 150mVp-p 150mVp-p 150mVp-p 150mVp-p
Voltage regulation range 10~13.2V 10~13.2V 20~26.4V 26~30V 41~56V
Voltage accuracy ±1.0% ±1.0% ±1.0% ±1.0% ±1.0%
Linear adjustment rate ±0.3% ±0.3% ±0.2% ±0.2% ±0.2%
Load adjustment rate ±0.5% ±0.5% ±0.5% ±0.5% ±0.5%
Start, rise, hold time 1500ms,80ms,18ms/230VAC    3000ms,80ms,14ms/115VAC(At full load)
Input Voltage range 100~240VAC,142~339VDC
Frequency range 47~63Hz
Power factor PE>0.95/230VAC   PE>0.98/115VAC(full load)
Efficiency 0.88 0.88 0.89 0.895 0.905
Alternating current 5.3A/115VAC    2.65A/230VAC
Inrush current 20A/115VAC     40A/230VAC
Leakage current <2.0mA/240VAC
Protection Over duty 105% ~ 130% of rated output power
Protection mode: constant current limit, abnormal conditions can be automatically
restored after removal
Overvoltage 13.8~16.2V
Protection mode: Turn off the output voltage and recover after restart
Overtemperature Turn off the output voltage and recover automatically after
the temperature drops
RC+/RC-:0.8V: Power on; 4 to 10V: The power supply is off
Environment Remote control switch The maximum load line voltage drop compensation by remote sensing is 0.3V
Remote sensing RTH2≥50°C±10°C The fan is on. RTH2≤40°C±10°C Fan off (3.3~5V fan is always working,2~48V fan on/off control)
Fan Control (Typ) -30~+70°C(please refer to “Derating Curve”)
Safety Working temp,humidity 20%~90%RH,non-condensing
Storage temp& humidity -40℃ ~ +85℃; 10%-95% RH Non-condensing
Temperature coefficient ±0.03%/°C(0~50°C)
Vibration resistance 10 ~ 500Hz, 2G 10min./1 cycle, X, Y, Z axis, duration of 60 minutes
Fit standard Withstand voltage I/P-O/P:3KVAC  I/P-FG:2KVAC  O/P-FG:0.5KVAC
Insulation impedance I/P-O/P,I/P-FG,O/P-FG:100M ohms/500VDC/25°C/70%RH
Safety standard UL62368-1, EN/EN62368-1, GB4943.1
EMC emission Conforms to EN55032(CISPR22)Class B,IEC/EN61000-3-2, Class A
EMC immunity Comply with IEC/EN55035, IEC/EN61000-6-2, IEC/EN61000-4-2, 3, 4, 5, 6, 8
Other MTBF 1372.4K hrs min. Telcordia SR-332(Bellcore);187.9K hrs min. MIL-HDBK-217F(25°C)
Dimension 230*127*40.5mm (L*W*H)
Weight/packing 1.3kg/9pcs/12.7kg/0.7CUFT
Note 1. All parameters, unless otherwise specified, are measured at 230VAC input voltage, rated load and 25°C.
2. Ripple and noise voltages are measured on a 20MHz bandwidth oscilloscope with a 12-inch twisted pair
end and a capacitor of 0.1 μand 47 μ.
3. Accuracy: voltage setting error, linear adjustment rate and load adjustment rate.
4. Linear adjustment rate measurement method: under rated load, from low voltage to high voltage test.
5. Load adjustment rate measurement method: from 0% to 100% rated load.
6. The power supply should be considered as part of the components in the system, and the electromagnetic compatibility should be confirmed in conjunction with the terminal equipment.
Dimensional Drawing

Dimensional drawing

Block diagram

 

Product Function

This section describes the functions of the CN100

Pin number Feature Description
1 -S The inductive signal -,-S is connected to the negative end of the load. +S,-S should be twisted to minimize the impact of noise. The maximum line voltage drop can be compensated to 0.3V.
2 +S Inductive signal +,+S connected to the positive end of the load,+S,-S should use stranded wire to minimize the impact of noise, the maximum line voltage drop can be compensated to 0.3V.
3 RC- Return RC+ signal input
4 RC+ Power is turned on or off by an electronic switch or dry contact between pin 4(RC+) and PIN 3 (RC-). 0~0.8V: Power on,4~10V: power off

 

Function manual

Remote control

The PSU can be controlled on/off by remote control

 

Between RC+(pin3) and RC-(pin4) Output state
The switch is off (0 ~ 0.8V) or open Open
Switch on (4 ~ 10V) Close

 

Remote sensing

The maximum load line voltage drop compensation by remote sensing is 0.3V

Get A Quote

Further information or a personal consultation? Our products and know-how are there to provide solutions.

RELATED PRODUCTS
RELATED NEWS
YOU MAY ALSO WANT TO SEE
GET A QUOTE TODAY!
icon
icon
Seraphinite AcceleratorOptimized by Seraphinite Accelerator
Turns on site high speed to be attractive for people and search engines.