| Model | LPV-150N-12 | LPV-150N-24 |
| Output | DC output voltage | 12V | 24V |
| Load rated output current (CC) | 12.5A | 6.5A |
| Rated output power | 150W | 151.2W |
| Ripple noise (Max.) | 180mVp-p | 360mVp-p |
| Voltage accuracy | ±2% | ±2% |
| Linear adjustment rate | ±0.5% | ±0.5% |
| Load adjustment rate | ±2% | ±2% |
| Start, rise, hold time 25°C | 500ms,10ms,10ms/230VAC (full load) |
| Dynamic load characteristic | Test condition: Load ≥20Hz dynamic jump. Jump range: load rated current 6%~100% |
| Ripple <500mVp-p (dynamic load ripple is less than 5% of rated voltage, no obvious audible noise, input power is stable and does not flicker) |
| Input | Operating voltage range | Optional 220VAC(200~240VAC) or 110VAC(100~120VAC)(refer to derating curve) |
| Optional 220VAC±15%/110VAC±15% |
| 47~63Hz |
| <2.1A/110VAC;<0.9A/230VAC; |
| PF≥0.65/110VAC, PF≥0.55/230VAC(full load) |
| 93.8% (full load, input 230VAC, no line damage) |
| Cold start current <80A/230VAC |
| <0.75mA/240VAC |
| Protection | Overcurrent protection | Start overcurrent protection for 110%~115% of rated output current |
When approaching the set overcurrent threshold, the output voltage drops rapidly and
enters the state of isolation protection. The load can be automatically recovered after
abnormal conditions are removed |
| Overload protection | Start overload protection for 110%~115% of rated output current |
When approaching the overload power threshold, the load current and voltage drop rapidly
and enter the state of isolation protection. The load can be automatically recovered after
abnormal conditions are removed |
| Short circuit protection | When the load impedance is 0 ohm due to an abnormal load, the system enters the
isolation protection state and can be short-circuited for a long time |
| The load can be automatically recovered after abnormal conditions are removed |
| Environment | Operating temperature
and humidity | -20°C~+60°C; 20%~90%RH, no condensation |
Store temperature
and humidity | -40°C~+85°C; 10% to 95%RH, non-condensing |
Maximum enclosure
temperature | 65°C(measured at ambient temperature of 25°C) |
Shock resistance
and impact | 10Hz~500Hz, acceleration 2G 10min./1 cycle, duration 60 minutes, X, Y, Z axis for 6
sweep cycles |
| Safety | Insulation strength
and leakage current | I/P~O/P : 1.5KVAC/ < 10mA; I/P~FG : 1.5KVAC/ < 10mA;O/P~FG : 0.5KVDC/ < 10mA |
| Insulation impedance | Input and output: 10MΩ; Input and housing: 10MΩ; Output and housing: 10MΩ |
| Others | Dimension | 235*54*21mm(L*H*W) |
| Weight/packing | 0.56kg/36pcs/20.8kg/0.92CUFT/0.026cubic meters |
| Design MTBF | At 25°C, 100,000 Hrs, MIL-217 Method 2 Components Stress Method |
Design electrolytic
capacitor life | >2 years (test conditions: ambient temperature 50°C, input 230Vac, refer to derating
curve for details) |
| Note | 1. All parameters are measured at 230VAC voltage input, rated load and 25℃ when not specified.
2. Ripple and noise voltages are measured on a 20MHz bandwidth oscilloscope with a 12-inch twisted pair end and a capacitor of 0.1 μand 47 μ.
3. Voltage accuracy includes: voltage setting error, linear adjustment rate and load adjustment rate (voltage is the test value of the power port)
4. Linear adjustment rate measurement method: under rated load, from low voltage to high voltage test (voltage is the test value of the power port).
5. Load adjustment rate measurement method: from 0% to 100% rated load (voltage is the test value of the power port).
6. The power supply should be considered as part of the components in the system, and the electromagnetic compatibility should be confirmed in conjunction with the terminal equipment. |