ERP-350W series is a rain-proof AC to DC single-output closed power supply, with a stable voltage and constant current output design, using the international common AC input voltage range, with active power factor correction circuit, the whole series provides 24V output. Due to the conversion efficiency of up to 93%, the fanless design can work in the case temperature range of -30°C to 60°C under natural air cooling.
Features :
200 ~ 240VAC AC input (can withstand 300VAC surge input for 5 seconds)
Stable voltage constant current mode output
Protection characteristics: short circuit/over load/over voltage/over temperature
Natural air cooling
Irrigated semi-rubber rain proof design
With power-on display (LED)
Suitable for dry, wet and rainy environment
100% full load burn test
High efficiency, long life and high reliability
3-year quality guarantee
Application:
LED lights with lighting
LED luminous subtitles
LED mobile sign
Industrial instruments and equipment
Product Specifications
Specifications
Model
ERP-350-24
Output
DC output voltage
24V
Rated output voltage
14.6A
Output current range
0~14.6A
Output power
350.4W
Ripple noise
240mVp-p
Voltage accuracy
±1%
Linear adjustment rate
±0.5%
Load adjustment rate
±0.5%
Start, rise, hold time
2000ms,100ms,16ms/230VAC(full load)
Input
Input voltage range
200~240VAC,282~339VDC
Frequency range
47~63Hz
AC input current
3.0A/230VAC
Power factor
PF>0.5
Efficiency
0.93
Impulse current
Cold start current 50A/230VAC
Leakage current
<3.5mA/240VAC
Protection
Overload protection
Start overload protection for 105% to 135% of rated output power
Protection mode: constant current mode. Normal output can be automatically restored after abnormal conditions are removed
Short circuit protection
Protection mode: constant current mode. Normal output can be automatically restored after abnormal conditions are removed
Overvoltage protection
27.6 ~ 32.4V
Protection mode: Turn off the output voltage and restart for recovery
Overtemperature protection
Protection mode: Turn off the output voltage and recover automatically after the temperature drops
Environment
Operating temperature
-30°C~+60°C(please refer to the load reduction curve)
Working humidity
20% to 90%RH non-condensing
Store temperature and humidity
-40°C~+85°C; 10%-95% RH Non-condensing
Secure
Shock resistance
10 ~ 500Hz, 3G 10min./1 cycle, X, Y, Z axis, duration of 60 minutes
Pressure resistance
I/P~O/P :1.5KVAC I/P~FG :1.5KVAC O/P~FG : 0.5KVAC
Insulation resistance
I/P ~O/P, I/P~FG,O/P~FG : 100M Ohms/500VDC/25°C/70%RH
Meet the standard
Safety standard
Conforms to UL60950-1,TUV EN60950-1, IP44
EMC emission
Conforms to EN55022 Class A, GB9254 Class A
EMC immunity
Conforms to EN61000-4-2,3,4,5,6,8,11, En55024
Others
Dimension
215*118*50(L*W*H)
Package
0.85KG/20PCS/18 KG/1.31CUFT/0.037cubic meters
Note
1. All parameters are measured at 230VAC voltage input, rated load and 25℃ when not specified.
2. Ripple and noise voltages are measured on a 20MHz bandwidth oscilloscope with a 12-inch twisted pair end and a capacitor of 0.1 μand 47 μ.
3. Accuracy: voltage setting error, linear adjustment rate and load adjustment rate.
4. Linear adjustment rate measurement method: under rated load, from low voltage to high voltage test.
5. Load adjustment rate measurement method: from 0% to 100% rated load.
6. The power supply should be considered as part of the components in the system, and the electromagnetic compatibility should be confirmed in conjunction with the terminal equipment.
Dimensional Drawing
Dimensional Drawing
Block Diagram
Get A Quote
Further information or a personal consultation? Our products and know-how
are there to provide solutions.