The RSP-500W series is a 500W single-output housing type AC to DC power supply. The full range of input voltages ranges from 100 to 240VAC and provides DC outputs to meet most industrial needs. Each model can be air-cooled by an internal speed fan with an operating temperature of 70°C. In addition, the RSP-500W offers design flexibility with built-in features such as remote on/off control and remote sensing.
Features :
International universal full range of AC input
Built-in active PFC function
Efficiency up to 90.5%
Built-in DC fan for forced cooling
Remote control switch/remote sensing function
Protection type: short circuit/over load/over voltage/over temperature
3-year quality guarantee
Application:
Industrial control or automation devices
Test and measurement instruments
Laser related machines
Aging equipment
Specifications
Specifications
Model
RSP-500-12
RSP-500-15
RSP-500-24
RSP-500-27
RSP-500-48
Output
DC voltage
12V
15V
24V
27V
48V
Rated voltage
41.7A
33.4A
21A
18.6A
10.5A
Current range
0~41.7A
0~33.4A
0~21A
0~18.6A
0~10.5A
Rated power
500.4W
501W
504W
502.2W
504W
Ripple noise
150mVp-p
150mVp-p
150mVp-p
150mVp-p
150mVp-p
Voltage regulation range
10~13.2V
10~13.2V
20~26.4V
26~30V
41~56V
Voltage accuracy
±1.0%
±1.0%
±1.0%
±1.0%
±1.0%
Linear adjustment rate
±0.3%
±0.3%
±0.2%
±0.2%
±0.2%
Load adjustment rate
±0.5%
±0.5%
±0.5%
±0.5%
±0.5%
Start, rise, hold time
1500ms,80ms,18ms/230VAC 3000ms,80ms,14ms/115VAC(At full load)
Input
Voltage range
100~240VAC,142~339VDC
Frequency range
47~63Hz
Power factor
PE>0.95/230VAC PE>0.98/115VAC(full load)
Efficiency
0.88
0.88
0.89
0.895
0.905
Alternating current
5.3A/115VAC 2.65A/230VAC
Inrush current
20A/115VAC 40A/230VAC
Leakage current
<2.0mA/240VAC
Protection
Over duty
105% ~ 130% of rated output power
Protection mode: constant current limit, abnormal conditions can be automatically
restored after removal
Overvoltage
13.8~16.2V
Protection mode: Turn off the output voltage and recover after restart
Overtemperature
Turn off the output voltage and recover automatically after
the temperature drops
RC+/RC-:0.8V: Power on; 4 to 10V: The power supply is off
Environment
Remote control switch
The maximum load line voltage drop compensation by remote sensing is 0.3V
Remote sensing
RTH2≥50°C±10°C The fan is on. RTH2≤40°C±10°C Fan off (3.3~5V fan is always working,2~48V fan on/off control)
Fan Control (Typ)
-30~+70°C(please refer to “Derating Curve”)
Safety
Working temp,humidity
20%~90%RH,non-condensing
Storage temp& humidity
-40℃ ~ +85℃; 10%-95% RH Non-condensing
Temperature coefficient
±0.03%/°C(0~50°C)
Vibration resistance
10 ~ 500Hz, 2G 10min./1 cycle, X, Y, Z axis, duration of 60 minutes
Fit standard
Withstand voltage
I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
Insulation impedance
I/P-O/P,I/P-FG,O/P-FG:100M ohms/500VDC/25°C/70%RH
Safety standard
UL62368-1, EN/EN62368-1, GB4943.1
EMC emission
Conforms to EN55032(CISPR22)Class B,IEC/EN61000-3-2, Class A
EMC immunity
Comply with IEC/EN55035, IEC/EN61000-6-2, IEC/EN61000-4-2, 3, 4, 5, 6, 8
Other
MTBF
1372.4K hrs min. Telcordia SR-332(Bellcore);187.9K hrs min. MIL-HDBK-217F(25°C)
Dimension
230*127*40.5mm (L*W*H)
Weight/packing
1.3kg/9pcs/12.7kg/0.7CUFT
Note
1. All parameters, unless otherwise specified, are measured at 230VAC input voltage, rated load and 25°C.
2. Ripple and noise voltages are measured on a 20MHz bandwidth oscilloscope with a 12-inch twisted pair
end and a capacitor of 0.1 μand 47 μ.
3. Accuracy: voltage setting error, linear adjustment rate and load adjustment rate.
4. Linear adjustment rate measurement method: under rated load, from low voltage to high voltage test.
5. Load adjustment rate measurement method: from 0% to 100% rated load.
6. The power supply should be considered as part of the components in the system, and the electromagnetic compatibility should be confirmed in conjunction with the terminal equipment.
Dimensional Drawing
Dimensional drawing
Block diagram
Product Function
This section describes the functions of the CN100
Pin number
Feature
Description
1
-S
The inductive signal -,-S is connected to the negative end of the load. +S,-S should be twisted to minimize the impact of noise. The maximum line voltage drop can be compensated to 0.3V.
2
+S
Inductive signal +,+S connected to the positive end of the load,+S,-S should use stranded wire to minimize the impact of noise, the maximum line voltage drop can be compensated to 0.3V.
3
RC-
Return RC+ signal input
4
RC+
Power is turned on or off by an electronic switch or dry contact between pin 4(RC+) and PIN 3 (RC-). 0~0.8V: Power on,4~10V: power off
Function manual
Remote control
The PSU can be controlled on/off by remote control
Between RC+(pin3) and RC-(pin4)
Output state
The switch is off (0 ~ 0.8V) or open
Open
Switch on (4 ~ 10V)
Close
Remote sensing
The maximum load line voltage drop compensation by remote sensing is 0.3V