Our website uses cookies to improve your experience and record usage statistics. By using our site you consent to cookies as described in our Privacy Policy. We take your privacy and data security very seriously and all information collected will be kept strictly confidential.

Decline All Accept All

MDR 100W AC/DC High Power Industrial DIN Rail Power Supply

  • International universal full range of AC input
  • Protection type: short circuit/over load/over voltage/over temperature
  • ZCS/ZVS technology to reduce power loss
  • Natural air cooling
  • Mounting rail: TS-35/7.5 or TS-35/15
  • DC OK relay is activated
  • LED power indicator
  • No-load power loss: <1W
  • 100% full load burn-in test
  • 3-year quality guarantee

 

Get A Quote
Product Description

MDR-100W is designed with plastic housing, can effectively prevent the user’s electrical hazards, working efficiency of up to 88%, under the condition of air circulation, the whole series can work in the ambient temperature of -10°C to 60°C, it has a complete protection function and conforms to the home automation, industrial control equipment IEC/EN62368-1, Certification to IEC/EN55032 (CISPR32), IEC/EN61000-3-2) and other standards makes the MDR-100W a highly competitive power solution for home and industrial applications.

 

Application:

Home control system
Building Automation
Industrial control systems
Factory Automation
Mechanical and electrical equipment

 

Product Specifications

Specifications

Model MDR-100-12 MDR-100-24 MDR-100-48
Output DC output voltage 12V 24V 48V
Rated output current 7.5A 4A 2A
Output current range 0~7.5A 0~4A 0~2A
Rated power 90W 96W 96W
Ripple noise 120mvp-p 150mvp-p 200mvp-p
Voltage adjustment range 12~15V 24~30V 48~56V
Voltage accuracy ±1.0% ±1.0% ±1.0%
Linear adjustment rate ±1.0% ±1.0% ±1.0%
Load adjustment rate ±1.0% ±1.0% ±1.0%
Start, rise, hold time 3000ms,50ms,50ms/230VAC   3000ms,50ms,20ms/115VAC(At full load)
Input Input voltage range 100~240VAC,47~63Hz,141~339VDC
Power factor PF≧0.95/230VAC PF≧0.98/115VAC(full load)
Efficiency 0.83 0.86 0.87
Alternating current 1.3A/115VAC,0.8A/230VAC
Inrush current Cold start current  30A/115VAC,60A/230VAC
Leakage current <1mA/240VAC
Protection Overload protection 105%~150% of rated output power
Protection mode: constant current limit, automatic recovery after load abnormal conditions are removed
Overvoltage protection 15.6~18V 31.2~36V 57.6~64.8V
Protected mode: The output voltage is turned off and recovered after restart
Overtemperature protection Turn off the output voltage and recover automatically or after restart
Feature DC OK signal Relay contacts (Max.) : 30V/1A resistive load
Environment Working temp,humidity -20℃~+70℃,20%~90%RH
Storagetemp,humidity -40℃~+85℃,10%~95%RH non-condensing
Temperature coefficient ±0.03%/°C(0-50°C)
Withstand vibration 10~500Hz,2G 10min./1 cycle, X, Y, Z 60 minutes each; Installation: According to IEC60068-2-6
Safety Withstand voltage I/P-O/P:3KVAC   I/P-FG:2KVAC   O/P-FG:0.5KVAC
Isolated resistance I/P-O/P,I/P-FG,O/P-FG:>100M Ohms/500VDC/25℃/70%RH
Fit standard Safety standards IEC/EN62368-1, EN61558-1
EMC emission Complies with IEC/EN55032 (CISPR32) class A, IEC/EN61000-3-2, class A
EMC immunity Comply with IEC/EN55035, IEC/EN61000-6-2, IEC/EN61000-4-2, 3, 4, 5, 6, 8
Others Dimension 55* 90 * 100 mm ( W* H* D)
Weight/packing 0.42kg /30PCS /13.6 kg / 0.82 CUFT
Note 1. Unless otherwise specified, all parameters, unless otherwise specified, are measured at 230VAC voltage input, rated load and 25°C
2. Ripple and noise voltages are measured on a 20MHz bandwidth oscilloscope with a 12-inch twisted pair end and a capacitor of 0.1 μand 47 μ..
3. Accuracy: including setting error, linear adjustment rate and load adjustment rate.
4. The power supply is considered to be a separate component, but the final power supply still needs to be combined with the terminal equipment for electromagnetic compatibility related confirmation.
5. Start time is measured in cold start, frequent switching may lead to longer start time.
6. In the case of low voltage input, the output needs to be derated. For details, see the output derated curve.

Dimensional Drawing

Block Diagram

 

DC OK Relay Triggered

Contact closure The power supply /DC is normal
Contact open The power supply is off or the DC is faulty
Contact (Max.) 30V/1A resistive load

 

Get A Quote

Further information or a personal consultation? Our products and know-how are there to provide solutions.

RELATED PRODUCTS
RELATED NEWS
YOU MAY ALSO WANT TO SEE
GET A QUOTE TODAY!
icon
icon
Seraphinite AcceleratorOptimized by Seraphinite Accelerator
Turns on site high speed to be attractive for people and search engines.