LRS Ultra-thin Durable Enclosed Switching Power Supply 120W

  • International general AC voltage input
  • Can withstand 300vac surge input for 5 seconds
  • Small size (1U low shell), light weight
  • Protection characteristics: short circuit/over load/over voltage
  • Air cooling
  • Low no-load power (<1W)
  • Can be operated at an altitude of 2000 m (Note 6)
  • With power-on display (LED)
  • 100% full load burn test
  • High efficiency, long life and high reliability
  • LED power indicator
  • 2-year quality guarantee

 

Get A Quote
Product Description

The LRS-120E series is a 120W single-output enclosed power supply with a 30mm low profile design and a full range of AC inputs from 100 to 240VAC, offering 12V,15V,24V,36V and 48V outputs throughout the series.

 

Features :

International general AC voltage input
Can withstand 300vac surge input for 5 seconds
Small size (1U low shell), light weight
Protection characteristics: short circuit/over load/over voltage
Air cooling
Low no-load power (<1W)
Can be operated at an altitude of 2000 m (Note 6)
With power-on display (LED)
100% full load burn test
High efficiency, long life and high reliability
LED power indicator
2-year quality guarantee

 

Application:

Industrial automation machinery
Industrial control systems
Mechanical and electrical equipment
Electronic instruments, equipment and devicesces

 

Product Specifications

Specifications

Model LRS-120E-12 LRS-120E-15 LRS-120E-24 LRS-120E-36 LRS-120E-48
Output DC voltage 12V 15V 24V 36V 48V
Rated current 10A 8A 5A 3.3A 2.5A
Current range 0~10A 0~8A 0~5A 0~3.3A 0~2.5A
Rated power 120W 120W 120W 118.8W 120W
Ripple&noise 120mVp-p 150mVp-p 240mVp-p 400mVp-p 500mVp-p
Adjustable range of DC voltage ±10% ±10% ±10% ±10% ±10%
Excellent voltage ±2% ±1% ±1% ±1% ±1%
Linear adjustment rate ±0.5% ±0.5% ±0.5% ±0.5% ±0.5%
Load adjustment rate ±1% ±0.5% ±0.5% ±0.5% ±0.5%
Start, rise, hold time 800ms,30ms,55ms/230VAC(At full load)
Input Input voltage range 100~240VAC,47~63Hz,141~339VDC
AC input voltage 2.3A/115VAC  1.4A/230VAC
Efficiency 0.88 0.885 0.9 0.905 0.91
Surge current Cold start current 50A/230VAC
Leakage current <0.75mA/240VAC
Over load Start overload protection for 110% to 150% of rated output power
Protection mode: In isolation mode, normal output can be automatically restored after abnormal conditions are removed
Overvoltage protection Start overvoltage protection for 120%~150% of rated output voltage
Protection Protection mode: In isolation mode, normal output can be automatically restored after abnormal conditions are removed
Environment Working temp,humidity -20℃~+60℃,20%~90%RH
Storage temp& humidity -40℃~+85℃,10%~95%RH non-condensing
Withstand vibration 10~500Hz, 3G 10min./1 cycle, duration 60 minutes, each axis
Safety Withstand voltage I/P-O/P:1.5KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
Isolated resistance I/P-O/P,I/P-FG,O/P-FG:100M ohms/500VDC/25°C/70%RH
Fit standard Safety standards Conforms to UL60950-1, IEC/EN62368
EMC emission Conforms to EN55032(CISPR22)Class A,IEC/EN61000-3-2, Class A
EMC immunity Comply with IEC/EN55035, IEC/EN61000-6-2, IEC/EN61000-4-2, 3,4, 5,6, 8
Others Dimension 129*97*30mm (L*W*H)
Weight/packing 0.35kg/54pcs/21.5kg/0.035m³/1.24CUFT
Note 1. All parameters, unless otherwise specified, are measured at 230VAC input voltage, rated load and 25°C.
2. Ripple and noise voltages are measured on a 20MHz bandwidth oscilloscope with a 12-inch twisted pair end and a capacitor of 0.1 μand 47 μ.
3. Accuracy: voltage setting error, linear adjustment rate and load adjustment rate.
4. Linear adjustment rate measurement method: under rated load, from low voltage to high voltage test.
5. Load adjustment rate measurement method: from 0% to 100% rated load.
6. When the operating altitude is higher than 2000 m (6500ft), adjust the operating environment by 5°C/1000 m.
7. The power supply should be considered as part of the components in the system, and the electromagnetic compatibility should be confirmed in conjunction with the terminal equipment.

Dimensional Drawing

Dimensional drawing

Block diagram

 

Get A Quote

Further information or a personal consultation? Our products and know-how are there to provide solutions.

RELATED PRODUCTS
RELATED NEWS
YOU MAY ALSO WANT TO SEE
GET A QUOTE TODAY!
icon
icon
Seraphinite AcceleratorOptimized by Seraphinite Accelerator
Turns on site high speed to be attractive for people and search engines.