Our website uses cookies to improve your experience and record usage statistics. By using our site you consent to cookies as described in our Privacy Policy. We take your privacy and data security very seriously and all information collected will be kept strictly confidential.

Decline All Accept All

600W Low-Cost High Power Ultra-thin Enclosed Power Supply

  • General communication input voltage: 110VAC/220VAC, switchable
  • Small in size, lightweight, and high in efficiency
  • Protection features: short circuit/overload/overvoltage/overtemperature
  • Forced air cooling, intelligent thermal management, optimized fan lifespan
  • It has strong load adaptability and can handle inductive loads
  • 100% full-load burn-in test
  • LED power indicator, output voltage adjustable
  • 2-year quality guarantee
Get A Quote
Product Description

The LRS-600W series is a 600W single output enclosed power supply with a 41mm low profile design. It adopts 115VAC or 230VAC segmented input (selected by switch), and the entire series provides 24V, 36V, and 48V outputs. In addition to achieving an efficiency of up to 92%, the LRS-600W is equipped with a long-lasting DC fan that allows it to operate at full load within a temperature range of -20 ° C to+60 ° C.

 

Features :

General communication input voltage: 110VAC/220VAC, switchable
Small in size, lightweight, and high in efficiency
Protection features: short circuit/overload/overvoltage/overtemperature
Forced air cooling, intelligent thermal management, optimized fan lifespan
It has strong load adaptability and can handle inductive loads
100% full-load burn-in test
LED power indicator, output voltage adjustable
2-year quality guarantee

 

Application:

Industrial automation machinery
Industrial control system
Mechanical and electrical equipment
Electronic instruments, equipment

 

Product Specifications

Specifications

Model LRS-600-24 LRS-600-36 LRS-600-48
Output DC output voltage 24V 36V 48V
Output voltage tolerance ±2% ±2% ±2%
Rated output current 25A 16.6A 12.5A
Output current range 0~25A 0~16.6A 0~12.5A
Output power 600W 597.6W 600W
Ripple noise 300mVp-p 400mVp-p 500mVp-p
DC voltage adjustable range ±10% ±10% ±10%
Start, rise, hold time 600ms,50ms,20ms/230VAC   800ms,30ms,20ms/115VAC
Input Input voltage range 100~120VAC/200~240VAC,47~63Hz,282~339VDC
AC input voltage 7.4A/115VAC  3.7A/230VAC
Efficiency 0.91 0.92 0.92
Surge current Cold start current 35A/115VAC   65A/230VAC
Leakage current <3.5mA/240VAC
Protection Over load Start overload protection for 105% to 135% of rated output power
Protection mode: fixed current limit, load abnormal conditions can be automatically restored after removal
Overvoltage protection 115% ~ 135%
Protection mode: In isolation mode, abnormal conditions can be automatically restored after removal
Overtemperature protection ≥85°C±5% Start overtemperature protection
Protection mode: In isolation mode, the temperature can be automatically restored after returning to normal
Function Fan On/Off Control (Typ.) RTH3≥50°C fan on, ≤40°C fan off
Environment Working temp,humidity -20℃~+60℃,20%~90%RH
Storage temp& humidity -40℃~+85℃,10%~95%RH non-condensing
Withstand vibration 10~500Hz, 3G 10min./1 cycle, duration 60 minutes, each axis
Safety Withstand voltage I/P-O/P:1.5KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
Isolated resistance I/P-O/P,I/P-FG,O/P-FG:100M ohms/500VDC/25°C/70%RH
Fit standard Safety standard Conforms to UL60950-1, IEC/EN62368
EMC standard Conforms to EN55032(CISPR22)Class A,IEC/EN61000-3-2, Class A
Others Dimension 225*124*41mm(L*W*H)
Weight/packing 0.95kg/18pcs/17.9kg/1.18CUFT/0.033m³
Note 1. All parameters, unless otherwise specified, are measured at 230VAC input voltage, rated load and 25°C.
2. Ripple and noise voltages are measured on a 20MHz bandwidth oscilloscope with a 12-inch twisted pair end and a capacitor of 0.1 μand 47 μ.
3. Accuracy: voltage setting error, linear adjustment rate and load adjustment rate.
4. Linear adjustment rate measurement method: under rated load, from low voltage to high voltage test.
5. Load adjustment rate measurement method: from 0% to 100% rated load.
6. The power supply should be considered as part of the components in the system, and the electromagnetic compatibility should be confirmed in conjunction with the terminal equipment.
Dimensional Drawing

Dimensional drawing

1

Block diagram

2

3

 

Get A Quote

Further information or a personal consultation? Our products and know-how are there to provide solutions.

RELATED PRODUCTS
RELATED NEWS
YOU MAY ALSO WANT TO SEE
GET A QUOTE TODAY!
icon
icon
Seraphinite AcceleratorOptimized by Seraphinite Accelerator
Turns on site high speed to be attractive for people and search engines.