WDR-60W is an economical and slim 60W rail type power supply that meets German industrial standards. It is suitable for installation on TS-35/7.5 or TS-35/15 tracks and is designed with a width of 32mm inside the cabinet to save space.The entire series uses AC input from 180Vac to 500Vac. Designed with a metal shell, it is easy to improve the heat dissipation consumption of the machine, with a working efficiency of up to 90%. The entire series can operate in am bient temperatures ranging from -30 ℃ to 70 ℃ under air circulation conditions. It has a constant current mode overload protection function and is suitable for various inductive or capacitive load applications.
Features :
Input voltage range 180-500VAC/254-700VDC
Constant current design, suitable for complex equipment such as inductive and capacitive devices
Ultra wide operating temperature range, from as low as -30 ° C to as high as+70 ° C
Complete protection function, short circuit/overload/overvoltage
Double sided board reflow soldering process, higher reliability and consistency
100% full load aging test
DC-OK relay triggered
Application:
Industrial control system
Semiconductor manufacturing equipment
Factory automation
Mechanical and electrical equipment
Product Specifications
Specifications
Model
WDR-60-12
WDR-60-24
WDR-60-48
Output
DC output voltage
12V
24V
48V
Rated current
5A
2.5A
1.25A
Ripple and noise (Max)
120mVp-p
120mVp-p
150mVp-p
Voltage adjustment range
10.2~13.8V
21.6~27.5V
42~54V
Start-up and rise time
1000ms,30ms/400VAC; 1500ms,30ms/230VAC(full load)
Hold time
30ms/230VAC; 10ms/115VAC(full load)
Input
AC input current
180~500VAC 254~700VDC
Frequency range
50~60Hz
Efficiency
89%
89%
90%
Input current
0.4A/400VAC 0.70A/230VAC
Power factor
0.6A/400VAC 0.65A/230VAC
Surge current
50A
Leakage current
<3.5mA/400VAC
Protective
features
Overload protection
Start overload protection from 105% to 150% of rated output power
Protection mode: Output voltage <” At 50%, it is in hiccup mode and can automatically recover after the abnormal load conditions are removed
Output voltage at 50% to 100% for constant current mode, the load of an abnormal condition removed can be automatically restored
Overvoltage protection
14~17V
28~33V
55~65V
Protection mode: Hiccup mode, automatically recovers after abnormal conditions are removed
Short-circuit protection
Output positive and negative terminals short-circuited
Protection mode: Hiccup mode, automatically recovers after abnormal conditions are removed
Function
Function (DC-OK signal)
Relay contacts (maximum): 30V / 1A resistive load
48V without this feature
Environment
Operating environment
-30℃ to +70℃ (Please refer to the load reduction curve)
1. Unless otherwise specified, all parameters are the measured values under the conditions of 400VAC input voltage, rated load and 25°C.
2. The ripple and noise voltages were measured with a 20MHz bandwidth oscilloscope at the end of a 12-inch twisted pair cable with 0.1μ and 47μ capacitors.
3. Accuracy: includes set error, linear adjustment rate and load adjustment rate.