Ultra-thin PFC-Standard Enclosed Switching Power Supply 350W

  • Universal AC input range (90~264VAC)
  • Protections:Short circuit/Overioad/Over voltage/Over temperature
  • Forced air cooling by built-in DC fan
  • Built-in active PFC function(PF>0.95)
  • Operating altitude up to 5000 meters
  • 100% full load burn-in test
  • High efficiency,long life and high reliability
  • 3 years warranty

 

Get A Quote
Product Description

RSP-350 is a 350W single output enclosed type AC to DC power supply.This series operates for 90~264VAC input voltage and offers the models with the DC output mostly demanded fromthe industry. Each model is cooled by the built-in fan with fan speed control, working for thetemperature up to 70°C.

 

Features :

Universal AC input range (90~264VAC)
Protections:Short circuit/Overioad/Over voltage/Over temperature
Forced air cooling by built-in DC fan
Built-in active PFC function(PF>0.95)
Operating altitude up to 5000 meters
100% full load burn-in test
High efficiency,long life and high reliability
3 years warranty

 

Application:

Factory control or automation apparatus
Test and measurement instrument
Laser related machine
Burn-in facility
RF application

 

Specifications

Specifications

Model RSP-350-12 RSP-350-24 RSP-350-48
Output DC voltage 12V 24V 48V
Rated voltage 29A 14.6A 7.3A
Current range 0~29A 0~14.6A 0~7.3A
Rated power 348W 350.4W 350.4W
Ripple noise 150mVp-p 200mVp-p 240mVp-p
Voltage regulation range 10~13.2V 20~26.4V 41~56V
Voltage accuracy ±1.0% ±1.0% ±1.0%
Linear adjustment rate ±0.2% ±0.2% ±0.2%
Load adjustment rate ±0.5% ±0.5% ±0.5%
Start, rise, hold time 1000ms,50ms,15ms/230VAC    2000ms,50ms,10ms/115VAC(At full load)
Input Voltage range 90~264VAC,127~370VDC
Frequency range 47~63Hz
Power factor PF>0.95/230VAC 
Efficiency 0.87 0.88 0.89
Alternating current 4.5A/115VAC    2.5A/230VAC
Inrush current 20A/115VAC     40A/230VAC
Leakage current <2.0mA/240VAC
Protection Over duty Rated output power:105%~130% Start overload protection
Protection type:hiccup mode,auto-recovery after fault condition is removed
Overvoltage Rated output voltage 115%-120% Start over voltage protection
Protection type:cut off the output,auto-recovery after fault condition is removed
Overtemperature 95°C±10°C(RTH3 detect beside magnetic core)
Protection type:cut off the output,auto-recovery after the temperature become normal
Safety Fan Control (Typ) RTH2­≥50℃±10℃ Fan on; RTH2≤40℃± 10°C Fan off
Working temp,humidity -30~+70°C(please refer to “Derating Curve”)
Storage temp& humidity 20%~90%RH,non-condensing
Temperature coefficient -40℃ ~ +85℃; 10%-95% RH Non-condensing
Vibration resistance 10 ~ 500Hz, 3G 10min./1 cycle, Period for 60min, Each axes
Fit standard Withstand voltage I/P-O/P:3KVAC  I/P-FG:1.5KVAC  O/P-FG:0.5KVAC
Insulation impedance I/P-O/P,I/P-FG,O/P-FG:100M ohms/500VDC/25°C/70%RH
Safety standard Compliance to UL 62368-1,TUV EN 62368-1,KC 62368-1
EMC emission Compliance to EN 55032(CISPR22)Class B,GB9254 Class B,EN 61000-3-2,3
EMC immunity Compliance to EN 61000-4-2,3,4,5,6,8,11,EN 55024,EN 61000-6-1
Other MTBF ≥1460K hrs min. MIL-HDBK-217F(25°C)
Dimension 215*115*30 mm(L*W*H )
Weight/packing 0.9kg/24pcs/21.6kg/0.027m³/0.96CUFT
Note 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25°C of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1μ & 47μ parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Line regulation is measured from low line to high line at rated load.
5. Load regulation is measured from 0% to 100% rated load.
6. The ambient temperature derating of 5℃/1000 m is needed for operating altitude greater than 2000m(6500ft).
7. The power supply is considered as a component which will be installed into a finalequipment,The final equipment must be re-confirmed that it still meets EMC directives, For guidance on how to perform these EMC tests.
Dimensional Drawing

Dimensional drawing

Block diagram

 

Get A Quote

Further information or a personal consultation? Our products and know-how are there to provide solutions.

RELATED PRODUCTS
RELATED NEWS
YOU MAY ALSO WANT TO SEE
GET A QUOTE TODAY!
icon
icon
Seraphinite AcceleratorOptimized by Seraphinite Accelerator
Turns on site high speed to be attractive for people and search engines.