HPV-35E series is a waterproof AC to DC LED drive power supply, to regulate the voltage output design, using the international common AC input voltage range, the whole series provides 12V,24V output. Due to the conversion efficiency of up to 85%, the fanless design can work in the case temperature range of -20℃ to +60℃ under natural air cooling.
Features :
International common AC input voltage range
Stabilized mode output
Built-in active PFC circuit
Protection feature: short circuit/over load
Natural air cooling
Fully protected aluminum housing
Full glue filling, in line with IP65/IP67 protection grade, indoor/outdoor installation
Suitable for dry, wet and rainy environment
100% full load burn test
High efficiency, long life and high reliability
2-year quality guarantee
Application:
LED street lighting
LED wall wash light
LED patio lights
LED greenhouse lighting
LED floodlight
Start overload protection for 110% to 150% of rated output power
Protection mode: In isolation mode, normal output can be automatically restored after
abnormal conditions are removed
Environment
Operating temperature
-20℃~+60℃
Working humidity
20%~90%RH,non-condensing
Storage temp& humidity
-40℃~+85℃,10%~95%RH non-condensing
Shock resistance
10 ~ 500Hz, 3G 10min./1 cycle, X, Y, Z axis, duration of 60 minutes
Safety
Pressure resistance
I/P-O/P:1.5KVAC
Insulation resistance
I/P-O/P:100M ohms/500VDC/25°C/70%RH
Fit standard
Safety standard
Conforms to UL60950-1,TUV EN60950-1, IP67
EMC emission
Compliant with EN55015, EN61000-3-2 Class C(≥50% load), EN61000-3-3, GB17743,GB17625.1
EMC immunity
Conforms to EN61000-4-2,3,4,5,6,8,11, En55024, EN61547
Others
Dimension
258*30*19mm (L*W*H)
Weight/packing
0.25kg/64pcs/17kg/0.025m³/1.24CUFT
Note
1. All parameters are measured at 230VAC voltage input, rated load and 25℃ when not specified.
2. Ripple and noise voltages are measured on a 20MHz bandwidth oscilloscope with a 12-inch twisted pair end and a capacitor of 0.1 μand 47 μ.
3. Accuracy: voltage setting error, linear adjustment rate and load adjustment rate.
4. Linear adjustment rate measurement method: under rated load, from low voltage to high voltage test.
5. Load adjustment rate measurement method: from 0% to 100% rated load.
6. The power supply should be considered as part of the components in the system, and the electromagnetic compatibility should be confirmed in conjunction with the terminal equipment.